C.U.E. has created a polyurthane materials data chart for your information and assistance in selecting the right polyurethane for your needs. For a PDF version of the polyurethane materials data chart click the icon at the right or click here. |
|
|
Typical Properties of Compound No.
|
PO-645
|
PO-655
|
PO-670
|
PO-650
|
PO-652
|
CU-290
|
PO-658
|
|
Shore Durometer
(ASTM D2240-64T) |
45A
|
60A
|
70A
|
86A
|
93A
|
90A
|
58D
|
|
Compression set:
(ASTM D395-61 Method B) 22 Hrs. @ 158Fo |
15% Max
|
30% Max
|
35%Max
|
45% Max
|
25% Max
|
30% Max
|
35% Max
|
|
Ultimate Tensile Strength |
2300
|
3000
|
4000
|
6000
|
5000
|
6500
|
5000
|
|
|
|||||||
|
Tensile Modulus ( ASTM D412-61T )
|
|||||||
|
@ 50% Elongation (psi)
|
85
|
50
|
400
|
500
|
1100
|
900
|
2300
|
|
@ 100% Elongation (psi)
|
120
|
115
|
500
|
700
|
1600
|
1100
|
2600
|
|
@ 200% Elongation (psi)
|
170
|
250
|
850
|
985
|
1900
|
1650
|
3000
|
|
@ 300% Elongation (psi)
|
190
|
300
|
900
|
1600
|
2300
|
2200
|
3500
|
|
Elongation at Break
(ASTM D-412-61T) |
700%
|
625%
|
550%
|
550%
|
550%
|
475%
|
400%
|
|
Tension at Break
(ASTM D-412-61T) |
--
|
5%
|
5%
|
25%
|
35%
|
--
|
30%
|
|
|
|||||||
| Tear Strength (lbs./in.) | |||||||
|
Trouser Die
(ASTM D1938) |
45
|
40
|
200
|
250
|
400
|
230
|
250
|
|
Die C
(ASTM D624) |
100
|
240
|
400
|
470
|
630
|
500
|
620
|
|
Split Tear
(ASTM D470) |
20
|
25
|
70
|
140
|
200
|
110
|
220
|
|
|
|||||||
| Compression-Deflection (Load Carrying Ability) ASDM D575-46, Method A |
|||||||
|
5%
|
20 psi
|
50 psi
|
65 psi
|
200 psi
|
450 psi
|
150 psi
|
700 psi
|
|
10%
|
40 psi
|
110 psi
|
130 psi
|
375 psi
|
750 psi
|
350 psi
|
1150 psi
|
|
25%
|
100 psi
|
300 psi
|
375 psi
|
1000 psi
|
1900 psi
|
1000 psi
|
3000 psi
|
|
|
|||||||
| Abrasion: ( Tabor Test: H18 wheel, mg1000 cycles ) ( NBS Test: % Rubber Standard ) |
|||||||
|
Tabor ASTM D3489-85(90)
|
17
|
17
|
23
|
15
|
44
|
- -
|
42
|
|
NBS ASTM D1630-83
|
165
|
180
|
205
|
250
|
385
|
- -
|
222
|
|
|
|||||||